Acoustic test cabin

ASTM C423 · SAE J2883 · ISO 15186 · 250 to 10 kHz · Acoustic camera included

Ideal for diffuse-field sound absorption (NRC, SAA, Aw) and transmission loss (Rw, STC) of small size samples.

Description

Mecanum’s acoustic test cabin (alpha cabin) measures diffuse-field sound absorption (NRC, SAA, Aw) and transmission loss (Rw, STC) of small size samples between 250 and 10 000 Hz. Both tests run in a single setup, which makes it an efficient tool for research and development, quality control, supplier validation, and benchmarking. Originally developed for automotive OEMs and suppliers, it is now used just as widely to evaluate building insulation and soundproofing materials. It follows ASTM C423, SAE J2883, and ISO 15186.

Tech specs

Performance

Frequency range

250 Hz to 10 kHz ⅓ octave frequency band

Maximum sound level

110 dB

Maximum STC % Rw

45

Dimensions & weight

Interior dimensions

2.53 m x 1.34 m x 1.66 m (5.62 m³)

Exterior dimensions

2.80 m x 1.70 m x 2.10 m

Weight

1200 kg

Samples

Absorption test samples

0.36 m² up to 1.3 m²

Transmission test samples

Up to 61 cm x 61 cm x 10 cm

Software

Alpha-X

Alpha-X guides you through diffuse-field sound absorption measurement in a single, intuitive window. Its robust TR60 slope-detection algorithm extracts absorption automatically and consistently, whoever runs the test, and you refine the post-processing on the spot with intuitive cursors, switching between time-data and Schroeder-integration views as needed. Air dissipation is corrected automatically per ANSI/ASA S1.26, a detail that matters for high-frequency precision, and NRC, SAA, and αw display directly. One click produces a standards-compliant Excel report with everything the norms require.

TL-X

TL-X takes you through diffuse-field transmission loss measurement in the same straightforward single-window design. It keeps you confident in your data with a live PI-Index display of measurement quality, shows STC and Rw directly, and lets you compare projects and compute insertion loss with built-in tools. As with Alpha-X, a one-click Excel report gives you clean, standards-ready documentation.

SONOCAM

SONOCAM’s software helps you get the transmission setup right before you measure. Its acoustic-camera leak finder captures images during sample installation, so you can confirm the seal is airtight and install every sample the correct way, every time.

Applications

Automotive

Measure the absorption and transmission loss of trim, headliners, and seals to hit cabin noise targets before tooling.

Aerospace

Characterize lightweight insulation and composite panels to balance acoustic performance against strict weight budgets.

Building

Evaluate partition, ceiling, and facade materials for sound insulation and absorption to meet acoustic comfort and code requirements.

Material manufacturers

Generate reliable NRC, SAA, and STC data on small samples to qualify new formulations and support product datasheets.

Laboratories

Run diffuse-field absorption and transmission loss measurements when floor space or budget rules out a large chamber.

Universities

Give students and researchers a compact, standards-compliant setup for testing without a full-scale reverberation room.

Accessories

SONOCAM: Now included with your cabin

Scroll to Top