Home / Acoustic solutions / Services / Impedance tube testing service

Impedance tube testing

NSAC, NSTL · 35 Hz to 10 kHz · ISO 10534-2 · ASTM E1050 · ASTM E2611 · Custom setups

We measure normal-incidence sound absorption (NSAC) and transmission loss (NSTL) of your materials, with high-resolution data from 35 Hz to 10 kHz.

Description

Fast, precise analysis of your material’s acoustic properties by impedance tube. Mecanum measures the normal sound absorption coefficient and normal sound transmission loss across a wide frequency range, from 35 Hz to 10 kHz, to support material development, quality control, and product certification. Reliable impedance tube data is the foundation on which sound absorption, insulation, and overall acoustic performance are optimized.

Our methods

Conventional impedance tube

ISO 10534-2 · ASTM E1050 · ASTM E2611

Standard normal-incidence absorption and transmission loss on small samples, the versatile workhorse for most materials.

Mecanum 29 mm impedance and transmission tube - Absorption and transmission loss - ASTM E1050 ASTM E2611 ISO 10534-2

Square impedance tube

ISO 10534-2 · ASTM E1050 · ASTM E2611

Square cross-section testing for acoustic metamaterials and non-conventional geometries.

Mecanum 38.1 square impedance and transmission tube - Absorption and transmission loss for metamaterials - ASTM E1050 ASTM E2611 ISO 10534-2

High-frequency impedance tube

ISO 10534-2 · ASTM E1050

Absorption measurement up to 10 kHz, the high-frequency range typical of electric motors and eVTOL propulsion.

Mecanum high frequency impedance and transmission tube - For electriv vehicule and eVTOL - ASTM E1050 ISO 10534-2

High-level impedance tube

ISO 10534-2 · ASTM E1050 · ASTM E2611

Setups for extreme environments, including aircraft engine liners, at sound pressure levels up to 150 dB.

Mecanum high level impedance and transmission tube - Absorption and transmission loss - Up to 155 dB - ASTM E1050 ASTM E2611 ISO 10534-2

Custom setups

Unique configurations such as grazing-incidence excitation or other bespoke test setups for demanding requirements.

Custom solutions for impedance tube testing - Grazing incidence

Workflow

01

Describe

your materials and frequency range of interest

02

Send

your samples with our handling guidance

03

We measure

absorption and/or transmission loss

04

Receive

a full reporting including results and high-resolution curves

Applications

Automotive

Characterize absorption and transmission loss of trim and insulation materials on small samples for fast NVH development.

Aerospace

Test engine liners and lightweight absorbers, including high-level and grazing-incidence configurations for nacelle materials.

Building

Characterize construction and insulation materials early in development, before scaling up to full partition or room testing.

Material manufacturers

Validate absorption and transmission loss on small samples to qualify formulations and support quality control.

Laboratories

Obtain fast, standards-compliant absorption and transmission loss data on limited sample sizes.

Universities

Access high-resolution normal-incidence measurements across a wide frequency range for research and teaching.

Scroll to Top